The status lamp on the front of the LiveShell PRO indicates the broadcasting status by color.
While the power is off:
- Red light:
- The AC adapter is connected and charging.
- 5 second red light –> Off
- The AC adapter is connected but does not need to charge.
- 4 red blinking lights at intervals of 0.5 seconds
- The AC adapter is connected, but the battery is not inserted.
- Continued red blinking at intervals of 0.5 seconds
- The AC adapter is connected, but the LiveShell PRO is not charging because of a battery error.
While the power is on:
- Stuck queues are under 32
- Blue light.
- Stuck queues are 33 – 64 during broadcasting
- Green light.
- Stuck queues are 64 – 128 during broadcasting
- Yellow blinking lights at intervals of 1 second.
- Stuck queues are 128 – 192 during broadcasting
- Red blinking light at intervals of 1 second.
- Stuck queues are over 192 during broadcasting
- Red blinking light at intervals of 0.5 seconds.
- Wi-Fi adapter or the ethernet cable has been detached during broadcasting
- Red blinking light at intervals of 0.25 seconds.
- LiveShell’s display says “Reconnecting”
- Red blinking at intervals of 0.25 seconds.
- Very low battery
- Yellow blinking light at intervals of 0.25 seconds.